Toyota Corolla + 1. Maintenance instruction + 2. Maintenance - 3. Engines + 3.1. Petrol engines + 3.2. Diesel engine - 3.3. Engine electric equipment 3.3.1. Specifications 3.3.2. Battery 3.3.3. Power cables 3.3.4. Ignition system 3.3.5. Ignition coil 3.3.6. Ignition distributor 3.3.7. Check and installation of the moment of ignition 3.3.8. Block of electronic ignition 3.3.9. Induction sensor 3.3.10. System of a charge of the battery 3.3.11. Generator 3.3.12. Generator details 3.3.13. System of start-up of the engine 3.3.14. Starter electric motor + 4. Systems of cooling, heating + 5. Fuel, exhaust systems + 6. System of decrease in toxicity + 7. Transmissions + 8. Coupling and semi-axes + 9. Brake system + 10. Suspension bracket and steering + 11. Body + 12. Electric equipment
|
Generator details (standard option)
1. Back cover 2. Shchetkoderzhatel 3. Insulating plug 4. Rectifier assembled 5. Rubber buffer 6. Back flange of the case 7. Holder 8. Gryazeotrazhatel 9. Tension regulator 10. Cover of a shchetkoderzhatel 11. Contact plate of the rectifier
|
12. Rotor 13. Bearing cover 14. Back bearing 15. Forward bearing 16. Pulley 17. A forward cover (assembled with a stator) 18. Holder 19. Bearing cover 20. Persistent washer |
Details of installation and generator drive
1. Drive belt 2. Coupling bolt 3. Lock bolt |
4. Main wire of the generator 5. Adjusting bolt 6. Generator 7. Socket |
Removal
PERFORMANCE ORDER |
1. Disconnect the battery from weight. |
|
2. Disconnect from the generator sockets. |
3. Weaken adjusting, coupling and lock bolts of the generator (see fig. Details of installation and generator drive). |
4. Turn on and get adjusting and coupling bolts from an adjusting arm of the generator. |
5. Remove the generator and an arm from the engine. |
6. If you decided to replace the generator, at acquisition of the new unit grasp with yourself the old generator. Be convinced that new (or repaired) the generator in accuracy corresponds to the replaced. Pay attention to conclusions – their number, the sizes and a relative positioning should be same, as on the replaced unit. At last, check marking. Marking should be or is stamped on the case, or printed on a label and pasted on the case. Be convinced that numbers on new and replaced units coincide.
|
7. On many new (or repaired) generators there are no pulleys therefore it is necessary to rearrange a pulley from the replaced unit. At acquisition of the new generator consult concerning pulley installation, in some workshops and sale points consultation is given free of charge.
|
|
|
|