Toyota Corolla

1992-1998 of release

Repair and car operation



Toyota Corolla
+ 1. Maintenance instruction
+ 2. Maintenance
+ 3. Engines
- 4. Systems of cooling, heating
   4.1. Specifications
   4.2. Antifreeze
   4.3. Thermostat
   4.4. Fan and relay of turning on of the fan
   4.5. Radiator and broad tank
   4.6. The pump of cooling liquid
   4.7. The sensor of temperature of cooling liquid
   4.8. Fan block
   4.9. Heater radiator
   - 4.10. Control panel heater and conditioner
      4.10.1. Central air
   4.11. Vlagootodelitel of the conditioner
   4.12. Compressor
   4.13. Condenser
   4.14. Evaporator and broad valve
+ 5. Fuel, exhaust systems
+ 6. System of decrease in toxicity
+ 7. Transmissions
+ 8. Coupling and semi-axes
+ 9. Brake system
+ 10. Suspension bracket and steering
+ 11. Body
+ 12. Electric equipment



4.10. Control panel heater and conditioner

GENERAL INFORMATION

Scheme of check of short circuit of contacts of the switch of speed of rotation of the fan

The switch is in the situation "Low" – contacts 3 and 7 are closed
In the situation "M1" – contacts 3, 7 and 8 are closed
In the situation "Sq.m" – contacts 3, 6 and 7 are closed
In the situation "HI" – contacts 3, 7 and 8 are closed

Removal and installation

PERFORMANCE ORDER
1. Disconnect the battery from weight.
2. Remove decorative overlays of average control panels (see subsection 11.21).
3. Get heads of regulators.
4. Unscrew fastening screws from the control panel face. Disconnect sockets.
5. Submit the panel on itself a little. Turn tags (it is specified by an arrow) in places of fastening of covers of cables of management. Remove cables from the control panel. Disconnect sockets.
6. Installation is carried out upside-down.
7. Start the engine, check existence of leaks and work of systems of heating and conditioning (if is available).

Adjustment of a cable of management

PERFORMANCE ORDER
1. After fixing of cables on the control panel and after installation of the control panel it is necessary to adjust tension of cables. Handles of management transfer to the provisions RECIRC, COOL and DEF.
2. For adjustment of a cable of management by a zaslonka of an air inlet transfer a control lever a zaslonka to the situation RECIRC (2). Fix in a place an earring of a cable and a collar (1) cover of a cable.
3. For adjustment of a cable of management by a zaslonka of a regulator of air temperature transfer a zaslonka to the situation COOL (2). Fix in a place an earring of a cable and a collar (1) cover of a cable, slightly pulling a cover.
4. For adjustment of a cable of management by a delitelny zaslonka establish a zaslonka in the situation DEF (1). Fix an earring of a cable and a collar (2) covers of a cable.

Check

PERFORMANCE ORDER
1. Check the conditioner switch. By pressing the switch button (inclusion) contacts 5 and 6, and also 1 and 3 should be closed накоротко.
2. Check serviceability of the switch of speed of rotation of the fan (see fig. Scheme of check of short circuit of contacts of the switch of speed of rotation of the fan). If contacts of the switch do not become isolated according to the enclosed scheme, replace the control panel assembled.