1. To merge liquid from cooling system. |
2. Remove the fuel pump of a high pressure as it is described in subsection 3.2.20. |
3. Remove an average cover of a gear belt. |
4. Unscrew the water pump. It fastens on seven bolts. Pay attention to an arrangement of bolts as they have various length. Remove laying. |
5. Installation is made upside-down. Surely establish new laying. Bolts tighten the moment of 18 N of m. |
6. The fuel pump and a gear belt are established how is described in subsection 3.2.20 and subsection 3.2.2. Adjust a tension of a maple belt of the generator and fill in liquid in cooling system. |